Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller

Explore our factory-made 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller from the Similar Delta/Ls/FUJI H500 Series. High-quality and reliable performance.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
H300-02D2T4G
Function
Simple Type, Elevator Special, Textile Special
Color
Black
Input Frequency
50/60Hz
Input Voltage
Three Phase, 380V
Control Modes
Open Vector Control(SVC), V/F Control
Certificate
ISO9001, CE
Wanrranty
2years
Lead Time
7-10 Working Days
Transport Package
Carton/Wooden Box
Specification
142*85*110mm
Trademark
H-WISE
Origin
Zhejiang, China
HS Code
8504409999
Production Capacity
100000per/Year

Product Description

Product Description:
H300 series simple inverter  has a wide range of speed regulation,high accuracy, fast dynamic response, high operating efficiency, easy to operate and a series of advantages, mainly used in textile machinery, machine equipment, fan, pump load and other occasions. 

Power class:    220V 1pH ,0.4-2.2KW 
                              380V 3pH ,0.75-5.5KW


Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller
             
Name plate :


Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller



Product Features:

Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller

Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller


H300 Series Model:
Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller

H300 Series Techinical Standard:
Item Specifications
Basic functions Control system Current Vector General Purpose Inverter.
Compatible motor Induction motors.
Maximum frequency Vector control: 0~500Hz;  
V/F control: 0~500Hz.
Carrier frequency 0.8kHz~12kHz; Depending on load, can automatically adjust.
Input resolution Digital: 0.01Hz;   Analog: maximum frequency×0.1%.
Control modes Open vector control (SVC);  
V/F (scalar) control.
Starting torque G type: 0.5Hz/150% (SVC); 0Hz/180% (FVC).
P type: 0.5Hz/100%.
Speed range 1: 100 (SVC) 1: 1000 (FVC)
Speed accuracy ±0.5% (SVC) ±0.02% (FVC)
Torque accuracy ±5% (FVC)
Overload capacity G type: 150% rated current 60s; 180% rated current 3s;  
P type: 120% rated current 60s; 150% rated current 3s.
Torque boost Automatic Manual 0.1%~30.0%
V/F curve Straight-line V/F curveMulti-point V/F curveN-power V/F curve (2-power, 1.4-power, 1.6-power, 1.8-power, 2-power square)
V/F separation Two types: complete separation; half separation. AVR output.
Ramp mode Straight-line rampS-curve rampFour groups of acceleration/deceleration time:  0.0-6500.0s
DC braking DC braking frequency: 0.00 Hz to maximum frequency
Braking time: 0.0-36.0s
Braking action current value: 0.0%-100.0%
JOG control JOG frequency range:  0.00-50.00 Hz
JOG acceleration/deceleration time:  0.0-6500.0s
Simple PLC Up to 16 speeds via the simple PLC function or DI terminals
Onboard PID Process-controlled closed loop control system
Auto voltage
regulation (VR)
Keep constant output voltage automatically when grid voltage fluctuates.
Overvoltage/
Overcurrent stall
control
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/overcurrent.
Fast current limit function Protect inverter from overcurrent malfunctions.
Torque limit and
control
It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the FVC mode.
Power DIP ride
through
The regenerative energy from load compensates the voltage reduction so that the inverter can continue to run for a short time.
Timing control Time range: 0.0-6500.0 minutes
Two-motor
switchover
Two motors can be switched over via two groups of motor parameters.
Fieldbuses RS485  
Operations Command source KeyboardControl terminalsSerial communication portYou can perform switchover between these sources in various ways.
Frequency source 10 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. You can perform switchover between these sources in various ways.
Auxiliary
frequency source
10 auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis.
Input terminal 5 digital input (DI) terminals;
2 analog input (AI) terminals which support 0-10V voltage input or 0-20mA current input.
Output terminal 1 digital output (DO) terminal;
1 relay output terminal;
1 analog output (AO) terminals which support 0-20mA current output or 0-10V voltage.
Display and panel Key lock It can lock the keys partially or completely and define the function range of some keys so as to prevent misconducts.
Protection functions Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltage protection, under voltage protection, overheat protection and overload protection
Environment Location Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
Altitude Less than 1000m.
Ambient
temperature
-10°C to +40°C (de-rated if the ambient temperature is between 40°C and 50°C)
Humidity Less than 90%RH, without condensing
Vibration Less than 5.8m/s2 (0.6g).
Storage
temperature
-20ºC~+60ºC.


Standard wiring diagram:

Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller
Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller

Scope of application:
H300 series inverter is widely used in winding machine, fan, pump load, woodworking equipment, lifting equipment,printing bag and other occasions, especially in textile machinery, with good energy saving effect.

Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller         


Application online images:
Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller

DIMENSION:(UNIT:MM)

Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller
Inverter  model Dimensions(mm) Holes(mm) Net(Kg)
H300-02D2T4G H W D A B
142 85 110 73 130 φ4.5 0.9


Factory outline:
Similar Delta/Ls/FUJI H500 Series 2.2kw 3 Phase 380V Frequency Inverter/VFD/Motor Controller

FAQ : 

1,Can I get some samples?
Yes, Sample order is available for quality check and market test .Sample product,buy one set product (1.5KW or 2.2KW)and  get free one set product(0.4KW or 0,75KW).

2,What's delivery time?
It usually takes 7-10 working days.

3,What's your warranty terms?
We offer 2 years warranty time.

4,Can the inverter connect with computer?
Yes, all inverters have built-in RS485 port and support Modbus communication protocol. 

5,How does your factory do the quality control?
Quality is priority ,we always attach the importance to quality control from the beginning to the end of the production .Every product will be fully assembled and carefully tested before packing and shipping .

6,Do you have the products in stock?
Depends on your request, we have standard models in stock. Some special products and big order will be newly produced according to your order.

7,Can you sell spare parts?

If you are using H-WISE products .we can sell spare parts to you.

8,How can I trust you?
Our company's values are integrity, responsibility, innovation and cooperation and our company has been audited and approved CE, ISO9001. Assessment report could be sent to you by e-mail. Also we are the made-in-China's Premium member supplier.               

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours